Qualified Products Home
635-Pull And Junction Boxes

A ) Meter Type Pull Box and Covers
Fabrication material for boxes and covers shall be: Polymer Concrete (box & cover); Sheet Moulding Compound (SMC) w/High Density Polymer Concrete collar (box) w/High Density Polymer Concrete (cover); Fiberglass Reinforced Polymer Concrete (box) w/ Fiberglass Reinforced Polymer (cover); Concrete Box (#38) w/ High Density Duo Mold & Composite Polymer Concrete; Cover Identification shall be engraved/molded and marked: “TRAFFIC SIGNAL”; ELECTRIC”; “TELEPHONE”; or “STREET LIGHTING” with 1-1/8 inch minimum legend height; “MIAMI-DADE PWD” w/5/8 inch minimum legend height; “20K” or “TIER 15” w/minimum 1/2 inch legend height; Two (2) SS Hex Head Bolts opposite corners to secure cover to box; FDOT APL Certification Number shall be stenciled or engraved on inside of box and underside of cover; Maximum weight of Box (w/o cover): 130 lbs.; Minimum weight of Cover: 35 lbs. (ANSI/SCTE 77 2007 or latest revision thereof)
FDOT_APL_NOAPPROVALMANUFACTURERDEVICE_DESCRIPTION
6351014002602305/28/1997Armorcast Products Co.Dwg # A6001946TAPCX12
6351014041313303/18/2010CDR Systems Corp. (Hubbell)Dwg # A24132412AR81
6351014170704301/20/2006NewBasisDwg # C1003266
6351014021010304/07/1995Oldcastle PrecastDwg # 1324-12 CPC (04/26/11)
6351014210106307/05/2001Quazite Division of HubbellDwg # P05198
6351014244801304/11/2005Synertech Molded ProductsDwg # 1324-12 PPC (04/26/11)

A1 ) Meter Type Pull Box and Covers: (Refer to Notes)
Approved for use when pullboxes and conduits are installed independent of County owned/maintained conduits and boxes. Boxes and Cover requirements same as “A” above, with following Exceptions: Cover Identification shall be engraved/molded and marked with acronym: “T I D” with 1-1/8 inch minimum legend height; In lieu of “MIAMI-DADE PWD” shall have no ownership name listed; “20K” or “TIER 15” w/minimum 1/2 inch legend height]. (ANSI/SCTE 77 2007 or latest revision thereof)

NOTES: FDOT Traffic Infraction Detectors (TID) a.k.a. Red Light Running Camera System (RLRC) EQUIPMENT and MATERIALS FOR USE & OPERATION OF TRAFFIC INFRACTION DETECTOR EQUIPMENT QPL APPROVAL REQUIRED FOR DEVICES WHEN INSTALLED WITH PWWM TRAFFIC SIGNAL EQUIPMENT (NOTE: Equipment Owned, Operated and Maintained by the Traffic Infraction Detector Company)



Synertech Molded Productswww.synertechproducts.com
CDR Systems Corp. (Hubbell)www.cdrsystems.com
Armorcast Products Co.www.armorcastprod.com
NewBasiswww.newbasis.com
Quazite Division of Hubbellwww.quazite.com

Oldcastle Precastwww.oldcastleprecast.com/enclosuresolutions

HISTORY:
CDR Pull Box Failures: MODEL SA24-1324-SERIES 12/18/2006 APL # 63510140413053 REMOVED from APL (2/12/09)
CDR Pull Box Redesigned with new FDOT APL (03/18/10)
Addition of “A-1” Pull Boxes & Covers for use w/TID equipment to QPL (03-03-11)

Last Modified on : 6/13/2012 12:36:19 PM