639-Electrical Power Service Assembly

A1 ) Service Disconnect - Heavy Duty Safety Switch (Main Disconnect)
NEMA Heavy Duty Type HD with NEMA 3R, outdoor enclosure (rainproof **); 60 Ampere, 120/240 Volt, Single Phase; Fusible, 2 Pole, 3-Wire; Replace with item “B” below when Traffic Infraction Detector (TID) equipment is connected to Main Disconnect; (Conformance with UL 98, Listed File E2875 or E154828; NEMA Standards Publication KS1, Enclosed Switches; Federal Specifications WS-865c for Type HD)
FDOT_APL_NOAPPROVALMANUFACTURERDEVICE_DESCRIPTION
N/A08/01/2009Cutler-Hammer (Eaton Corp.)DH222NRK/NEMA 3R
N/A08/01/2009General Electric Co. (GE)TH3222R/NEMA 3R
N/A09/22/2014Siemens Industry Inc.HF222NR (Type 3R) Heavy Duty Safety Switch with Equipment Ground Lug Kit (HG61234) and Neutral Kit (HN623)
N/A08/01/2009Square D Comapny(Schneider Electric)H222 NRB/NEMA 3R

A2 ) Service Disconnect - (Same as A1) Exception**: with NEMA 4X Enclosure - (Required on FDOT Projects)
Raintight, watertight, corrosion resistant, windblown dustproof outdoor enclosure; Type 304 Stainless Steel (Conformance with UL 98, Listed File E2875 or E154828; NEMA Standards Publication KS1, Enclosed Switches; Federal Specifications WS-865c for Type HD).
FDOT_APL_NOAPPROVALMANUFACTURERDEVICE_DESCRIPTION
N/A01/27/2011Cutler-Hammer (Eaton Corp.)DH222NWK or DH262NWK/NEMA 4X
N/A01/27/2011General Electric Co. (GE)TH3222SS/NEMA 4/4X
N/A09/22/2014Siemens Industry Inc.HF222S (Type 4X) Heavy Duty Safety Switch with Equipment Ground Lug Kit (HG61234) and Neutral Kit (HN623)
N/A01/27/2011Square D Comapny(Schneider Electric)H222 DS/NEMA 4/4X

B1 ) Service Disconnect - Heavy Duty Safety Switch (Main Disconnect Required with TID equipment):
NEMA Heavy Duty Type HD with NEMA 3R, outdoor enclosure (rainproof **); 60 Ampere, 120/240 Volt, Single Phase; Fusible, 3- Pole, 4- Wire; (Conformance with UL 98, Listed File E2875 or E154828; NEMA Standards Publication KS1, Enclosed Switches; Federal Specifications WS-865c for Type HD)
FDOT_APL_NOAPPROVALMANUFACTURERDEVICE_DESCRIPTION
N/A08/01/2009Cutler-Hammer (Eaton Corp.)DH322NRK/NEMA 3R
N/A08/01/2009General Electric Co. (GE)TH4322R/NEMA 3R
N/A09/22/2014Siemens Industry Inc.HF222NR (Type 3R) Heavy Duty Safety Switch with Equipment Ground Lug Kit (HG61234) and Neutral Kit (HN623)
N/A08/01/2009Square D Comapny(Schneider Electric)H322 NRB/NEMA 3R

B2 ) Service Disconnect - (Same as B-1) Exception**: with NEMA 4X Enclosure - (Required on FDOT Projects)
Raintight, watertight, corrosion resistant, windblown dustproof outdoor enclosure; Type 304 Stainless Steel (Conformance with UL 98, Listed File E2875 or E154828; NEMA Standards Publication KS1, Enclosed Switches; Federal Specifications WS-865c for Type HD)
FDOT_APL_NOAPPROVALMANUFACTURERDEVICE_DESCRIPTION
N/A01/27/2011Cutler-Hammer (Eaton Corp.)DH322NWK or DH362NWK/NEMA 4X
N/A01/27/2011General Electric Co. (GE)TH4322SS/NEMA 4X
N/A09/22/2014Siemens Industry Inc.HF222S (Type 4X) Heavy Duty Safety Switch with Equipment Ground Lug Kit (HG61234) and Neutral Kit (HN623)
N/A01/27/2011Square D Comapny(Schneider Electric)H322 DS/NEMA 4X

C ) 40 & 15 Amp Fuses for Service Disconnect - Heavy Duty Safety Switch
Dual-Element, Time-Delay Fuses [10 seconds (minimum) at 500% rated current]; 250 Volt; Interrupting Rating: 200,000A RMS Sym. DC Ratings: 20,000 A/C @ 125 VDC (UL Standard 248-12, Class RK-5, Guide JDDZ)
FDOT_APL_NOAPPROVALMANUFACTURERDEVICE_DESCRIPTION
N/A08/01/2009Cooper Bussman Inc.Fusetron FRN-R-15
N/A08/01/2009Cooper Bussman Inc.Fusetron FRN-R-40
N/A08/01/2009Ferraz ShawnutTri-Onic TR15R
N/A08/01/2009Ferraz ShawnutTri-Onic TR40R

D ) Outdoor Load Center (Secondary Disconnect Required for TID equipment): (Refer to Notes)
NEMA 3R outdoor, rainproof enclosure; Current Rating 100 Amps, Copper wire size #8-1 AWG; 120/240 VAC, Single Phase w/ 40 Amp, 2-pole, Main Circuit Breaker and 20 Amp, Single pole, Branch Circuit Breakers w/ AIR Rating 10Ka (Conformance with Federal Specification W-P-115c as Type 1 Class 2; UL and NEMA Standards)
FDOT_APL_NOAPPROVALMANUFACTURERDEVICE_DESCRIPTION
N/A01/25/2011Square D Comapny(Schneider Electric)QO6-12L100RB/Series G04

E ) Transient Protection Device
Refer to Section 620-Grounding and Lightning Protection. Only Surge Protective Devices (SPDs) that are listed on the FDOT Approved Products List (APL) and that meet the Materials requirement of Section 620 (Grounding and Lightning Protection) of the Florida Department of Transportation (FDOT) “Standard Specifications for Road and Bridge Construction” may be used within the Miami-Dade County traffic control and intelligent transportation systems. Use FDOT certified SPDs that and meet all applicable requirements for the equipment being protected unless more stringent requirements to protect existing systems are specified by the Miami-Dade County Traffic Signals and Signs (TSS) Division. Any use-appropriate SPD certified under FDOT APL Section 620 may be used by manufacturers of pre-wired cabinets as long as they meet the manufacturer’s design and performance requirements and all applicable FDOT and TSS Division specifications for the equipment.

NOTES: FDOT Traffic Infraction Detectors (TID) a.k.a. Red Light Running Camera System (RLRC) EQUIPMENT and MATERIALS FOR USE & OPERATION OF TRAFFIC INFRACTION DETECTOR EQUIPMENT QPL APPROVAL REQUIRED FOR DEVICES WHEN INSTALLED WITH PWWM TRAFFIC SIGNAL EQUIPMENT (NOTE: Equipment Owned, Operated and Maintained by the Traffic Infraction Detector Company)



Square D Comapny(Schneider Electric)www.squared.com
Siemens Industry Inc.w3.usa.siemens.com/powerdistribution/us/en/Pages/low-medium-voltage.aspx
Cooper Bussman Inc.www.bussmann.com
Cutler-Hammer (Eaton Corp.)www.eaton.com
General Electric Co. (GE)www.geindustrial.com
Ferraz Shawnutwww.ferrazshawnut.com

HISTORY:
Addition of Main and Secondary Disconnects for use w/TID equipment to QPL (12-01-10)
Addition of Outdoor Load Center for use w/TID equipment to QPL (01-25-11)
Addition of Stainless Steel NEMA 4X Enclosure; “A-2” & “B-2” required use on FDOT Projects to QPL (01-28-11)
Addition of Transient Protection Device for use w/all Service Disconnect switches to QPL (12-22-11)