Qualified Products Home
660-Vehicle Detector

A ) Loop Amplifiers
(Compliance with PWWM Traffic Signals & Signs Division technical specification: Traffic Controller Assemblies Specifications, 2007 Edition).
FDOT_APL_NOAPPROVALMANUFACTURERDEVICE_DESCRIPTION
6601355080204106/24/2005Eberle Design Inc.LM222
6601355080208112/31/2008Eberle Design Inc.LMD222

B ) Loop Sealant
Two-component Polyester Loop Sealant; self leveling; permanently flexible; shall withstand corrosive effect of road salts, automotive fluids, jet fuel, gasoline and extreme weather conditions; rapid curing with extreme adhesion to concrete and asphalt
FDOT_APL_NOAPPROVALMANUFACTURERDEVICE_DESCRIPTION
6601381071401304/16/1996Durant Performance CoatingsSTAT-A-FLEX (For Asphalt or Concrete)
6601382071401304/16/1996Durant Performance CoatingsSTAT-A-FLEX (For Asphalt or Concrete)
6601381070701306/17/1986Dynatron / (3M) Bondo Corp.Bondo P-606 (For Asphalt or Concrete)
6601382070701306/17/1986Dynatron / (3M) Bondo Corp.Bondo P-606 (For Asphalt or Concrete)

C ) Video
Video Image Processing (VIP) unit(s) and Communications Module shall be modular; mounted in Type 170 input file rack; control from 1 to 4 VIP boards; Serial (Programming Keypad) and Ethernet (TCP/IP) communications; communication to upload/download detector configurations, traffic data, events, software upgrades and remote set-up of detectors; MPEG-4 Video system communications module; Image Sensor shall be high resolution, 1/3" image format CCD camera w/motorized variable-focal 6.5-65mm lens with auto iris; Aluminum camera housing for outdoor CCD camera installations; Video camera(s) with IR filter enclosure and sunshield; Special Composite cable required, located under Section 632 - Signal and Interconnect Cable, item "G" Composite Cable (Power and Video); CCD Camera Mount Mast Arm Bracket, located under Section 659 - Signal Head Auxiliaries, item "N
FDOT_APL_NOAPPROVALMANUFACTURERDEVICE_DESCRIPTION
6601372121204103/10/2003Iteris Inc. (Odetic)+/-Ext Modules/Vantage Edge2-1N
6601372121205103/10/2003Iteris Inc. (Odetic)+/-Ext Modules/Vantage Edge2-2N

D ) Current Switch
For detection of Red and Yellow traffic signal phases for use with Traffic Infraction Detectors (T I D) and any other applications that require an on/off indication of AC current flow; Operating conditions: 112 VAC within +/- 32 VAC; Off-state leakage current maximum 50 ua; On-state continuous maximum 1.0 Amps AC RMS max.; Operating Temperature: -30° C to +60° C; Six (6) turns installation conformance required with device usage; (Conformance with IACP "Performance Specifications: Red Light Camera System Module", RLCS Performance Standards, Volume 1 dated 11/29/07)
FDOT_APL_NOAPPROVALMANUFACTURERDEVICE_DESCRIPTION
N/A11/24/2010CR Magnetics Inc.CR9350-ACA

E ) Wireless Magnetometer Assembly
Approved for use for detection of vehicles during Red and Yellow traffic signal phases with Traffic Infraction Detectors (T I D) only; not approved for Intersection Stop Bar Vehicle Detection; 8 -11 year lifetime battery powered; Temperature: - 40° F to + 185° F (- 40° C to + 85° C); (IEEE 802.15.4 Standard Compliant; NEMA 6P / IP 68)
FDOT_APL_NOAPPROVALMANUFACTURERDEVICE_DESCRIPTION
N/A11/24/2010Sensys Networks Inc.Model VSN240-f/Wireless Vehicle Detector

NOTES: FDOT Traffic Infraction Detectors (TID) a.k.a. Red Light Running Camera System (RLRC) EQUIPMENT and MATERIALS FOR USE & OPERATION OF TRAFFIC INFRACTION DETECTOR EQUIPMENT QPL APPROVAL REQUIRED FOR DEVICES WHEN INSTALLED WITH PWWM TRAFFIC SIGNAL EQUIPMENT (NOTE: Equipment Owned, Operated and Maintained by the Traffic Infraction Detector Company)

F ) Microwave
While inductive loop detectors continue to be the predominant vehicular detection type in Miami-Dade County, the site-specific use of alternate vehicular detection types, including the products listed below, will be considered on a case-by-case basis and may be limited to further pilot-scale evaluations on Miami-Dade County roadways
FDOT_APL_NOAPPROVALMANUFACTURERDEVICE_DESCRIPTION
660-026-00202/27/2012Wavetronix LLCSS-200V and SS-200E (SmartSensor Advance); SS-200V or SS-200E Sensor; Click 600; Click 112 or Click 114 detector rack card(s); ss710 junction box; cables 600v insulation rated including factory-terminated drop cable ; mount with Pelco Astro-Brac Clamp Kit (AB-3009), SH-0515 mount, and SE-0436-10 tube
660-018-00412/08/2010Wavetronix LLCSS225 SmartSensor Matrix; SS-225 Sensor; Click 600; Click 112 or Click 114 detector rack card(s); ss710 junction box; cables 600v insulation rated including factory-terminated drop cable; mount with Pelco Astro-Brac Clamp Kit (AB-3009), SH-0515 mount, and SE-0436-10 tube



Wavetronix LLCwww.wavetronix.com/en/products
Sensys Networks Inc.www.sensysnetworks.com
Durant Performance Coatingswww.durantcorp.com
Eberle Design Inc.www.editraffic.com
Dynatron / (3M) Bondo Corp.www.bondo.com
CR Magnetics Inc.www.crmagnetics.com
Iteris Inc. (Odetic)www.iteris.com

HISTORY:
Addition of Durant Performance Coatings to QPL (10-28-10)
Addition of Current Switch and Wireless Magnetometer Assembly for use w/TID equipment to QPL (12-01-10)
Addition of LMD222 Loop Amplifier to QPL (10-26-11)

Last Modified on : 12/23/2015 9:46:14 AM